300W 60000rpm 75V 4.5A CNC Spindle Motor 48mm ER8 Water-cooled High Precision High Speed for CNC Engraving Machines
GDZ48-300
Providing the default Nut ER8 and Collet 3.175mm, if not please do contact us for a better solution.
Specifications:
spindle motor model |
GDZ48-300 |
Brand |
Changsheng |
Certification |
ISO9001-2000 |
Product type |
High-Speed Constant Torque Motorized Spindle Motor |
Applications |
CNC Engraving Machine |
Pole number |
2 |
Rated power(KW) |
0.3Kw |
Rated voltage(V) |
75V |
Rated speed(rpm) |
60000 r/min |
Current(A) |
4.5A |
Frequency(Hz) |
1000Hz |
Cooling |
Water cooling |
Bearing type |
1×C136101 + 1×C136018 |
Lubricate |
grease |
Collet(mm) |
ER8, 3.175mm(default) |
Repair time |
bearing(half year),spindle(one year) |
Diameter D (mm) |
48mm |
Complete Length L(mm) |
120mm |
Run-out |
less than 0.005mm |
Notice |
The spindle motor must inverter VFD output, cannot directly connect power supply |
Applications:
PCB Engraving, Woodworking engraving, CNC drilling and milling.
Kindly note:
1. Motorized spindle motors are matched with inverters, choosing inverters should be according to the current, voltage, and frequency of motorized spindle motors.
- Setting the inverter must firstly set up the basal frequency, its basal frequency is based on the highest frequency of motorized spindle motor, if not setting the basal frequency (the factory setting is 50Hz),the motorized spindle motor would burn out once start running;
- the highest frequency, break frequency and the corresponding voltage also should be set according to the curve on the operating instruction; setting the current of the inverters is also based on the rated current of motorized spindle motor;
- the overcurrent is 120% of rated current; overload tripping is 100%, time is 5s;
- carrier frequency is set by the power of spindle motor,8kHz for less than 10KW motorized spindle motor, 5kHz is for more than 10KW spindle motor;
- the acceleration time and deceleration time are 10s and 20s respectively, if starting current exceed the rated current and need protection, it should extend the acceleration time.
- I/O lack-phase protection also should be set above the function of protecting inverters and motorized spindle motors.
- Connecting the inverter and the three-phase power of spindle motor, solder the inverter three-phase power cord on the plug 1(U1),2(V1),3(W1), plug 4 is ground wire. Then the inverter is connected with the external power supply and start work, then to check whether the rotation direction of spindle motor is consistent with its indication direction, if inconsistent, immediately shut down and change two wire on the three-phase power supply of connecting inverter and motorized spindle motor. The motorized spindle motor is prohibited running in the wrong rotation direction.
- Power lines should be taken waterproof and shielding measures. The connection between motorized spindle motor and inverter should not exceed 25m.When the power cord of the water-cooled spindle motor connects the terminal block, it must be bent into U shape and fixed on the bottom of the terminal block and then connect, so that can protect the condensed water of the power cord into the terminal block.
- Another, use shielding power lines to prevent its interference to inverter
Dear Friend, if you have any other demand, just let us know, we will try our best to help you. And if you want try air-cooled spindle motor, please kinldy check our to check the details.:)