1X 2.2KW ATC Spindle
1X 2.2KW VFD
Spindle Specification:
Brand:
Han Qi
Spindle Model:
GDL80-20-24Z-2.2
Dimension:
80mm*286.5mm
Speed:
24000rpm
Rated Power:
2.2kw
Voltage:
3-Phase AC 220V
Current:
7.6A
Frequency:
800HZ
Pole Number:
4P
Tool change signal: NPN / PNP
(PS: PNP and NPN are the different tool change information for the spindle)
Rotating direction: Rotate anticlockwise from the shaft extension end
Bearings:
2XHY6005C/P4 , 1XSM6004C/P4
Shaft End Connection:
ISO20 Tool Holder
Cooling Type:
Water Cooling
Lubricate:
Grease
Material: Stainless Steel Shell, Copper Coil
Diameter: 80mm
Cone Hole Runout: 2um
Manual:
VFD Basic Parameters:
Brand:
BEST
Model:
FC300-2.2G-S2
Adaptive Motor Power:
2.2KW
Input Voltage:
1-Phase 180~260V
Output Voltage:
3-Phase 0~220V
Current:
11A
Input Frequency:
50/60Hz
Output Frequency:
0~1000Hz
Control Method:
VVV/F Control and SVC(Open loop vector) Control
Level Of Protection:
IP20
Cooling Type:
Air-cooled
Note:
Please set the following parameters before using the Inverter:
P003 (rated frequency) = spindle rated frequency
P021 (highest frequency) = spindle rated frequency
If you adjust the frequency via the knob of the VFD panel , please set the following parameters:
P087=101
P064=0
P065=0
●1. Power line: Three-color lines connected with U, V and W phases/yellow and green wires grounded
Temperature control line:110°C thermistor two-phase connected with the temperature-control protector.
●2. Cooling water feed Pump lift 8m.
●3. Pole change and dust removal pressure 0.2-0,3Mpa (6/4 hoses).
●4. Quantity of proximity switches: Pole hanging and pole discharge NPN (normally open) N.O.
Wiring method of the proximity switch: Brown wire connected with +24VDC; blue wire connected with 0VDC;
Signal load end connected with +24VDC; the other end connected with the black wire.
●5. Air seal pressure 0.1-0.2Mpa (4/2 hoses).
●6. Cooling water yielding (2 and 6 ends terminated with 8/6 hoses).
●7. Air inlet pressure of the cylinder 0.65Mpa (6/4 hoses).
Special Warning:
●1. The electric main shaft shall be installed at the clamped position;
otherwise the bearing will be easily damaged!
●2. The main shaft shall entirely stop before the tool changing. The
manual tool changing button shall not act during the rotation of the
shaft; otherwise it will easily result in the seizure of the shaft!
●3. The compressed air shall be clean and dry, and the filter
accuracy shall be 0.1micron! Air seal is normally open. It is
recommended to use the two-level filter, and the filter accuracy is
0.5 micron/ 0.1 micron respectively. The air filter is installed with the
self-discharge device.
Reviews